CBHBP - CONDUCTIVITY REAGENT A

  • MSDS: CBHBP
  • Manufacturer: CALGON CORP
  • Product Name: CONDUCTIVITY REAGENT A
  • National Stock Number: 6630-00N068107
Product Identification

Product ID:CONDUCTIVITY REAGENT A
MSDS Date:05/23/1993
FSC:6630
NIIN:00N068107
MSDS Number: CBHBP

Responsible Party
CALGON CORP
PITTSBURGH, PA 15230-1346
US

Emergency Phone: 412-777-8000

Info Phone: 412-777-8000

Preparer: P J MALONEY

Cage: 86035

Contractor
CALGON CORP
1346 PITTSBURGH, PA 15230-1346 US

Telephone: 412-494-8000

Cage: 86035

Ingredients

(ORAL,RAT) 12600 MG/KG

CAS: 56-81-5

RTECS: MA8050000

Fraction By Weight: 66%

OSHA PEL 15 MG/M3 (MIST)

ACGIH TLV: 10 MG/M3 (MIST)


BORIC ACID. LD50 (ORAL,RAT) 2660 MG/KG

CAS: 10043-35-3

RTECS: ED4550000

Fraction By Weight: 14%

OSHA PEL 10 MG BORATES/M3

ACGIH TLV: 5 MG BORATES/M3


PRLNGD ABSORPTION OF BORIC ACID

RTECS: 9999999ZZ


ALOPECIA (LOSS OF HAIR), CONVL, & ANEMIA. BORIC ACID

RTECS: 9999999ZZ


RATS BY INGEST & INHAL. GLYCERIN ALSO HAS SHOWN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS:KIDNEY, SKIN.
ACUTE:EYE:MAY BE IRRIT UPON CONT. SKIN:GLYCERIN & BORIC ACID CAN
BOTH BE MILDLY IRRIT. GLYCERIN ABSORBS WATER & IN HIGH CONC IS
DEHYDRATING. BORIC ACID MAY BE ABSORBED THRU SKIN, PARTICULARLY
THRU DMG SKIN, CAUSING SKIN LESIONS, FEVER, & ANURIA (TOTAL
SUPPRESSION OF URINE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:FORMATION INDICATING KIDNEY DMG.)
INGEST:CONSIDERED TO BE MOD TOX BY INGEST SINCE CLINICAL LITERATURE
SUGGESTS THAT MAN IS MORE SENSITIVE TO BORIC ACID THAN RATS &
LETHAL DOSE AS LOW AS 200 M G/KG HAS BEEN RPTD. INGEST:GLYCERIN
CANCAUSE HDCH, DIZZ, INSOMNIA, NAUS, VOMIT, DIARR, & FEVER. @ VERY
HIGH (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:IMMEDIATELY FLUSH W/PLENTY OF WATER. SEEK MED AID IF
IRRIT PERSISTS. INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH
AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP) . SKIN:FLUSH W/COPI OUS
AMOUNTS OF WATER. CALL MD .

Fire Fighting

Flash Point:NOT FLAMMABLE
Extinguishing Media:THIS PRODUCT IS NOT FLAMMABLE/COMBUSTIBLE. WATER
FOG, CO*2, ALCOHOL FOAM, OR DRY CHEM. WATER/FOAM MAY CAUSE
FROTHING.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . EXERCISE CAUTION WHEN FIGHTING ANY CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:EMITS TOXIC GASES UNDER FIRE CONDITIONS.

Accidental Release

Spill Release Procedures:WEARING APPROP PERSONAL PROT EQUIP, CONTAIN
SPILL, COLLECT ONTO INERT ABSORBENT & PLACE INTO SUITABLE
CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE WITH ADEQUATE VENTILATION. KEEP
CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:IF AIRBORNE CONC EXCEED PUBLISHED EXPOS LIM, USE
NIOSH/MSHA APPRVD RESPIRATOR I/A/W OSHA RESP PROT REQUIREMENTS (29
CFR 1910.134).
Ventilation:USE LOCAL EXHAUST VENTILATION WHERE MIST OR SPRAY MAY BE
GENERATED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:AVOID CONT W/EYES & AVOID BRTHG MIST. AVOID
UNNECESSARY EXPOS TO PROD & ENSURE PROMPT REMOVAL FROM SKIN &
CLTHG.
Supplemental Safety and Health
EFTS OF OVEREXP:DOSES, GLYCERIN CAN CAUSE KIDNEY DMG. INGEST OF BORIC
ACID MAY ALSO CAUSE KIDNEY DMG & MAY PRDCE ABDOM CRAMPS, SKIN
LESIONS, RAPID HEART RATE, BLUISH SKIN, OR CONVL. INHAL:MIST MAY
CAU SE RESP TRACT IRRIT. BORIC ACID CAN BE ABSORBED THRU MUC MEMB
CAUSING TOX EFTS INCLDG SKIN LESIONS, FEVER, AND (ING 3)

Chemical Properties

Spec Gravity:>1.0
pH:ACIDIC
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:MISCIBLE
Appearance and Odor:PALE AMBER LIQUID WITH LITTLE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE, AND
BORIC OXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.